- 1/4 to 1/2 in. and 6 to 12 mm tubing sizes available in 316/316L Stainless Steel and Copper.
- Seamless , welded tubing and set tube stick available in Stainless Steel
- Jacketing materials available: TPU and PVC other materials available on customer request
- Pre-Insulated tube, contributes to the personnel safety
- Light and easy for installation
- Withstand tough weather conditions and most efficient in compare to pipe usage in steam applications

tube OD | Wall Thickness | Working Pressure | Max Process Temperature | Min Service and Installation Temperature | Min Jacket Tube OD* | Support Centers | Min Bend Radius | ||
mm | mm | bar | C° | C° | mm | m | cm | ||
Seamless | Welded | Horizontal | Vertical | ||||||
Annealed 316 Stainless Steel Tubing complying with ASTM A213 or A269 - Max Process Temperature 250°C | |||||||||
6 | 1.0 | 357 | 286 | 105 PVC Jacket | -34 Service | 28.60 | 1.80 | 4.60 | 20.00 |
1.2 | 459 | 367 | |||||||
10 | 1.0 | 204 | 163 | 32.60 | |||||
1.2 | 255 | 204 | 125 TPU Jacket*** | -23 Installation | 34.60 | ||||
12 | 1** | 170 | 136 | ||||||
1.2 | 212 | 170 | |||||||
Annealed Copper Tubing complying with ASTM B68, B75 - Max Process Temperature 200°C | |||||||||
6 | 1.0 | 55 | 1050 PVC Jacket | -34 Service | 28.60 | 1.80 | 4.60 | 20.00 | |
1.2 | 86 | ||||||||
10 | 1.0 | 34 | 32.60 | ||||||
1.2 | 55 | 125 TPU Jacket*** | -23 Installation | 34.60 | |||||
12 | 1** | 28 | |||||||
1.2 | 38 |
tube OD | Wall Thickness | Working Pressure | Max Process Temperature | Min Service and Installation Temperature | Min Jacket Tube OD* | Support Centers | Min Bend Radius | ||
in. | in. | psig | °F | °F | in. | ft | in. | ||
Seamless | Welded | Horizontal | Vertical | ||||||
Annealed 316 Stainless Steel Tubing complying with ASTM A213 or A269 - Max Process Temperature 482 °F | |||||||||
1/4 | 0.035 | 4420 | 3536 | 221 PVC Jacket | -30 Service | 1.14 | 6.00 | 15.00 | 8.00 |
0.049 | 6460 | 5168 | |||||||
3/8 | 0.035 | 2850 | 2280 | 1.26 | |||||
0.049 | 4122 | 3298 | 257 TPU Jacket*** | -10 Installation | 1.39 | ||||
1/2 | 0.035** | 2250 | 1800 | ||||||
0.049 | 3180 | 2544 | |||||||
Annealed Copper Tubing complying with ASTM B68, B75 - Max Process Temperature 400 °F | |||||||||
1/4 | 0.035 | 800 | 221 PVC Jacket | -30 Service | 1.14 | 6.00 | 15.00 | 8.00 | |
0.049 | 1250 | ||||||||
3/8 | 0.035 | 500 | 1.26 | ||||||
0.049 | 800 | 257 TPU Jacket*** | -10 Installation | 1.39 | |||||
1/2 | 0.035** | 400 | |||||||
0.049 | 550 |
Note: Standard Coating Wall Thichness 1.3mm (0.052'')
Note: Not recommended to use with Gas service
Maximum process temperature NOT continuous temperature rating which is 105 Deg C according to UL 1581.
Please contact us for more information about heat tolerance.
Specifications are for reference only and are subject to change without notice Actual product dimentions may vary from the catalog dimentions
WARNING! For Your Safety the system designer have the sole responsibility to select the products suitable for their special application requirements and to ensure the proper installation, operation and maintenance of the product. Please concider application details, material compatibility and product ratings when making your selection. Improper selection or use of products can cause property demage and or personal injury
The below tables provide the data for the loss of the heat energy in ralation to the change in the ambient temperature
The tubes are pre insulated with special fiberglass material as well coated with TPU or PVC material.
1/4'', 3/8'', 1/2'' (6 mm, 10 mm, 12 mm) Tubing - Heat Loss in Kcal/h-m Units | |||||||||
Ambient Temperature °C |
Process Temperature 250 °C Max surface Jacket Temperature 58 °C |
Process Temperature 200 °C Max surface Jacket Temperature 48 °C |
Process Temperature 150 °C Max surface Jacket Temperature 40 °C |
||||||
1/4’’ and 6 mm Tubing |
3/8’’ and 10 mm Tubing |
1/2’’ and 12 mm Tubing |
1/4’’ and 6 mm Tubing |
3/8’’ and 10 mm Tubing |
1/2’’ and 12 mm Tubing |
1/4’’ and 6 mm Tubing |
3/8’’ and 10 mm Tubing |
1/2’’ and 12 mm Tubing |
|
-50 | 48 | 63 | 70 | 40 | 52 | 58 | 32 | 42 | 46 |
-40 | 46 | 60 | 67 | 38 | 50 | 55 | 30 | 39 | 44 |
-30 | 45 | 58 | 65 | 36 | 47 | 53 | 28 | 37 | 41 |
-20 | 43 | 56 | 62 | 35 | 45 | 50 | 27 | 35 | 39 |
-10 | 41 | 53 | 59 | 33 | 43 | 48 | 25 | 33 | 36 |
0 | 39 | 51 | 57 | 31 | 41 | 45 | 23 | 30 | 34 |
10 | 37 | 49 | 54 | 30 | 38 | 43 | 22 | 28 | 31 |
20 | 36 | 47 | 52 | 28 | 36 | 40 | 20 | 26 | 29 |
30 | 34 | 44 | 49 | 26 | 34 | 38 | 18 | 24 | 27 |
40 | 32 | 42 | 47 | 25 | 32 | 35 | 17 | 22 | 24 |
50 | 31 | 40 | 44 | 23 | 30 | 33 | 15 | 20 | 22 |
1/4'', 3/8'', 1/2'' (6 mm, 10 mm, 12 mm) Tubing - Heat Loss in Btu/h-ft Units | |||||||||
Ambient Temperature °F |
Process Temperature 480 °F Max surface Jacket Temperature 136 °F |
Process Temperature 392 °F Max surface Jacket Temperature 120 °F |
Process Temperature 302 °F Max surface Jacket Temperature 104 °F |
||||||
1/4'' and 6 mm Tubing |
3/8’’ and 10 mm Tubing |
1/2’’ and 12 mm Tubing |
1/4’’ and 6 mm Tubing |
3/8’’ and 10 mm Tubing |
1/2’’ and 12 mm Tubing |
1/4’’ and 6 mm Tubing |
3/8’’ and 10 mm Tubing |
1/2’’ and 12 mm Tubing |
|
-60 | 53 | 71 | 78 | 45 | 59 | 65 | 36 | 47 | 52 |
-40 | 52 | 68 | 75 | 43 | 56 | 62 | 34 | 44 | 49 |
-20 | 49 | 65 | 72 | 40 | 53 | 59 | 32 | 41 | 46 |
0 | 47 | 69 | 72 | 38 | 50 | 55 | 29 | 38 | 43 |
20 | 45 | 59 | 65 | 36 | 47 | 52 | 27 | 36 | 39 |
40 | 43 | 56 | 62 | 34 | 44 | 49 | 25 | 33 | 36 |
60 | 40 | 53 | 59 | 32 | 42 | 46 | 23 | 30 | 33 |
80 | 38 | 50 | 56 | 30 | 39 | 43 | 21 | 28 | 31 |
100 | 36 | 48 | 53 | 28 | 36 | 40 | 19 | 25 | 28 |
120 | 34 | 45 | 50 | 26 | 33 | 37 | 17 | 22 | 25 |
NOTE: The maximum jacket surface temperature is 58 °C (136°F) with a process temperature of 250 °C (480°F), an ambient temperature of 24 °C(75.2°F) and a wind velocity of 12 km/h (7.45m/h)
Specifications are for reference only and are subject to change without notice Actual product dimentions may vary from the catalog dimentions
WARNING! For Your Safety the system designer have the sole responsibility to select the products suitable for their special application requirements and to ensure the proper installation, operation and maintenance of the product. Please concider application details, material compatibility and product ratings when making your selection. Improper selection or use of products can cause property demage and or personal injury
Build a Single, Thermal insulated or Own customer jacket tubing ordering number by combining the designators in the sequence shown below.
Ⅰ
|
Ⅱ
|
Ⅲ
|
Ⅳ
|
Ⅴ
|
||||
SJ | - | SS | - | 4-S-035 | - | TP | - | 250 |
Model
SJ = Single Jacket
TJ = Thermal-Insulated Jacket
CT = Customer Tube*
* UTC offers the unique coating services for the customer’s bare tubes. We accept coiled (on or without reel) and straight tubes. Read more at our UTC special service section in this catalog.
Material
SS = 316/316L Stainless Steel
CU = Copper
Other tubing materials may be offered on request
Tube Data
Size | Number per Inch, Number + M for MM size MM=6 , 10, 12, 18, 25 Inch: 4=1/4, 6=3/8, 8=1/2, 12=3/4, 16=1 |
Tube model | S (Seamless) W (Welded) ST (Stick of 6M) |
Wall Thickness | Number per Inch, Number +M for MM size |
Jacket Raw Material
TP = TPU
PV = PVC
Length
Number per feet
Number + M per Meter
On each jacket tube will be a marking of the following:
Manufacturer name, model, Coating material, Tube data, Process temperature, Batch No. (for traceability), Meter/Feet count Optionally a Caution Notice